IKO enertherm MG under the membrane: material compatibility and installation

At a glance

The MG system’s surface that bonds with the waterproofing is a coated glass fleece. It must not be replaced in the design with an aluminium laminate. The choice of membrane and fixing method must take the actual facing into account. The thermal parameter is the second condition to be checked for the chosen thickness. The section under consideration is a flat roof beneath a synthetic membrane. The IKO enertherm MG specification must be described together with the layers adjoining its surface. A key detail is the junction between the membrane and the fleece-faced board surface. The basis for coordination is a roof section with a confirmed membrane fixing method. Before choosing materials, the insulation thickness and the condition of the substrate before the waterproofing is laid must be established, so that the layer sequence refers to actual conditions.

Light matt board face, accompanying the guide to IKO enertherm MG beneath a membrane

Function of the board in the cross-section

A correct build-up should allow the thickness and a compatible method of connection to the membrane to be selected. The functions of the remaining layers must be defined separately.

The correct product and the scope of its data

In IKO enertherm MG, the PIR core is enclosed on both sides by perforated, coated glass fleece, and the complete board combines the properties of the core and the facings. For thicknesses below 120 mm, λD is 0.026 W/(m·K); from 120 mm, 0.025 W/(m·K); the RD of the 100 mm board is 3.80 m²K/W, and of the 120 mm board 4.80 m²K/W. The declared compressive strength is at least 150 kPa, the reaction to fire is E, and the manufacturer specifies use under synthetic membranes. This scope is a flat roof under a synthetic membrane, where the factory-made boards are laid in a defined layer build-up.

Scope of the example comparison

In IKO enertherm MG, the covering layer runs over the butt joints of the boards, and the support should prevent concentration of pressure. The d/λ calculation will not verify these conditions: for the example of 100 mm and a lambda of 0.026, it gives approximately 3.85 m²K/W. To achieve such resistance with a nominal lambda of 0.040, approximately 153.8 mm would be required. The result serves to compare layers; it does not declare the parameters of another product or the RD. Before accepting a roof variant, also check the connection of the fleece to the membrane and the fixing method, because thermal compatibility is only part of the assessment.

The calculation involving IKO enertherm MG describes the stated quantity, not automatically the class of the entire system. The key assumption is lambda 0.026 below 120 mm and 0.025 from 120 mm. The result must be compared with the limitation defined as a set of requirements for the coated glass fleece and the waterproofing. With regard to this cross-section, the compatibility of the covering layer with the coated glass fleece must be confirmed. A roof cross-section with a confirmed method of fixing the membrane, from which the position of each layer follows, is helpful. Only then can a covering with a synthetic membrane be considered in an agreed installation without automatically transferring the rules from another combination of materials.

How to assess the proposed change

The variant based on the decision of selecting the MG thickness for the required thermal resistance and the chosen covering must be considered through the full section. In the second step, the following action must be considered: reassessment of the entire system following a proposal for a different facing. With IKO enertherm MG, both proposals must preserve the requirements at the point described as the connection of the membrane to the board surface in the fleece. Any attribution to the MG board of a lambda of 0.022, which is proper to another variant, must be excluded, because such a simplification changes the basis of comparison. The final scope should be confirmed by the roof designer with the specific synthetic membrane. For the chosen solution, a description of the MG is needed covering the thickness, the format and the way the membrane works, consistent with the materials located directly below and above the insulation.

Surface and joint finish

The surface of IKO enertherm MG consists of a perforated, coated glass fleece. Its type must be taken into account when selecting the layer with which it will work. In the documentation, the simple contact of the boards under a continuous covering layer must also be identified, instead of replacing the actual geometry with a general symbol. Acceptance should be based on the record of the MG designation and the condition of the fleece before covering. For this reason, the covering with the synthetic membrane in the agreed installation should be carried out only after the agreed inspection. On the drawing, it is worth highlighting the connection of the membrane to the board surface in the fleece, because that is where the course of the connection changes.

The sequence of works follows from the build-up

Before laying IKO enertherm MG, support with protection against point loading must be ensured. The schedule should include inspection of the element described as the connection of the membrane to the board surface in the fleece. For acceptance, a roof section with the confirmed method of fixing the membrane must be prepared, indicating any execution changes. After this inspection, work can proceed to the scope that is the covering with the synthetic membrane in the agreed installation. The agreement of the sequence should be led by the roof designer with the specific synthetic membrane, especially when different layers are carried out by different teams. This makes it possible to separate the tasks that the polyurethane insulation has from the works ensuring the other functions of the section.

Specification ready for pricing

An enquiry for IKO enertherm MG should clearly indicate a flat roof under a synthetic membrane. The description must be accompanied by a description of the MG covering the thickness, the format and the way the membrane works, so that the supplier knows the adopted variant. A separate item may be the work needed to select the thickness and the compatible method of connection to the membrane. It is worth asking for a specification of the changes caused by any replacement of the facing or the geometry. Every such proposal should again take into account the set of requirements for the coated fleece and the waterproofing. After selecting the solution, the record of the MG designation and the condition of the fleece before covering must be kept as the basis for identifying the material on site. In such an order, the polyurethane boards are part of a specific system, not a category of freely interchangeable sheets.

7 branches. Materials closer to your project.

Sandwich-panel.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project