Kingspan PIR in roof systems: Therma TR26, TR27 and suitable facings

At a glance

Kingspan boards are selected by family and application, not by brand alone. Therma TR26 and TR27 have a PIR core, whereas Kooltherm is phenolic foam insulation. The facings also differ: TR26 has an aluminium-containing facing, while TR27 has a glass fibre facing. A substitution requires checking the connection to the covering, the fixing, and the thickness needed to achieve the thermal resistance. In this guide, we separate these criteria from the assessment of load-bearing capacity and fire requirements. We also show why the full product name and documentation of the actual cross-section are needed to compare offers and approve a substitute material.

Silvery surface and light-coloured cross-section of a PIR board against white and green fields

Role of the board in the assembly

If the project description gives only “Kingspan”, supplement it with the family, variant, core type and place of application. Therma PIR and phenolic Kooltherm do not identify the same material. Assign the correct declared-parameters document to the item defined in this way.

Interaction of adjacent layers

When changing from TR26 to TR27, the aluminium is replaced by a glass fibre surface. This interface with the next layer must correspond to the intended joint of the covering. The shared PIR name does not determine surface compatibility.

For a substitute, check the permitted method of jointing, the geometry of the sides and the finish of both boards. The drawing should preserve the function of each interface, including at the roof slope terminations. An assessment of the regular field is not sufficient when a material change affects the edges or flashings.

Changing from TR26 to TR27 may retain the PIR category, but it changes the surface that works with the covering, so equivalence must be checked at the interface between the materials. Also compare the thickness needed to achieve the required thermal resistance. Agreement of a single figure or a shared brand is not enough. The system is complete when the new variant retains all the functions assigned to the individual layers.

Behaviour of the completed building element

Therma insulation is not a complete sandwich panel with structural facings. In the cross-section, assign load-bearing capacity and fixing to the appropriate elements, and vapour control and protection against water to the designed sealing layers.

When switching Kingspan variants, maintain continuity of the membranes and flashings around the perimeter. A similar board colour does not confirm identical connection conditions. Compare the replacement product’s documentation with the layer sequence, sealing details and core protection in the planned roof.

Shared thermal objective

TR26 has a thermal conductivity of 0.022 W/(m·K), whereas the thermal conductivity of TR27 depends on thickness. Boards of the same height therefore do not necessarily provide the same thermal resistance. A comparison requires the parameters of the precisely specified variants.

To establish thermal equivalence, read the thermal conductivity and RD of each Kingspan variant ordered. Also check the effects of any change in cross-section height. The lowest value of one board cannot be attributed to the other families of this brand.

Material parameters and sequence of execution

The reaction to fire of the material is a different property from the fire resistance of the building element. Likewise, the compressive result at 10% deformation is not a ready design load. In the schedule of requirements, keep a separate scope for each test.

Link every requirement for the Kingspan system to the document that actually confirms it. A variant declaration describes the properties of the product; the load-bearing capacity and fire requirements of the whole cross-section need the relevant application documentation. One favourable material characteristic does not confirm all the functions of the building.

What changing the product changes

For a Kingspan offer, require the full name and thickness. When a substitution is proposed, assess the consequences for the adjacent layers instead of being guided by a similar PIR designation or colour. It is the scope of the complete solution that determines price comparability.

Add the necessary adjustment of geometry, fixings and adjacent layers to the cost of the Kingspan substitute. A lower price may result from a different application. Before purchase, define the criteria for equivalence, and on acceptance check compliance with the required thermal resistance and the updated documentation.

7 branches. Materials closer to your project.

Sandwich-panel.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project