XPS insulation
XPS beneath floors used by pallet trucks
At a glance
A pallet truck has small wheels, yet it can still carry a heavy load. For the floor, this means localised pressure and repeated movement. XPS under such a floor is selected together with the load-bearing layer, not on the basis of the truck weight stated in the offer. Extruded polystyrene can combine insulation performance with resistance to load. The prerequisite is knowledge of the actual operating conditions and verification of the entire floor assembly. The calculation requires the mass of the vehicle and of the goods being transported. The wheel spacing, the number of wheels and the way the pressure is transferred to the substrate are important. Two trucks with a similar load capacity do not necessarily load the floor in the same way.

The load needs to be described in more detail
Turning, braking and standing areas also matter. Information about the traffic helps to determine the requirements for the layer above the XPS.
Dividing the mass of all pallets by the hall area is not enough. The average obtained in this way ignores local loads. XPS under the transport aisle works in a different configuration from insulation under an empty part of the room. The designer needs a traffic plan and data on storage. If heavier transport is planned for the future, it must be taken into account before the new floor is constructed.
The load is distributed by the floor structure
The wheel should not move over exposed XPS. The load-bearing layer takes up the load and transfers it to a larger area of the substrate. How effectively it is distributed depends on the slab construction, its thickness, reinforcement and support. Extruded polystyrene is one element of this system. Its behaviour cannot be assessed without knowledge of the other layers.
At the edge of a slab or at a movement joint, the conditions differ from those at its centre. Greater displacements may occur at these locations. Even strong XPS will not eliminate a fault in the edge support. The design of the joints and of the force transfer must be adapted to the expected movement. This also applies to crossings between an older and a new part of the hall, where the substrates may differ in stiffness.
What the CS(10) value really says
The CS(10) designation refers to the stress at a specified deformation in a compression test. It is useful when comparing XPS, but it does not provide a ready load value to enter in the design. A ten per cent reduction in insulation thickness would be too great a change in a floor in use. Therefore the number on the label cannot be treated as a safe permanent pressure.
Extruded polystyrene is also selected with regard to deformation over time. The documentation is checked for creep data, and the design takes account of the assumed conditions and safety margins. If the required XPS property is marked NPD, it must not be replaced by an assumption. The relevant data for the application must be obtained, or a product selected whose documentation allows a reliable calculation to be carried out.
Even support reduces the risk of damage
XPS boards are laid on a substrate prepared in accordance with the design. Loose material, ridges in the concrete or settlement of the base cause uneven support. During vehicle movements, such places may behave differently from the adjacent surface. The insulation must not be used to mask unevenness. The substrate is repaired and checked first, and only then are the boards installed.
The joints of the XPS must be properly fitted, and damaged edges assessed before they are covered. Around service pipes, random voids should not be created. The way they are encased follows from the floor design. Extruded polystyrene can be cut to size, which makes accurate laying easier. However, the precision must serve even support, not merely the appearance visible before concreting.
Water from the wheels is also part of the operating conditions
Pallet trucks can bring in water from the yard, the cold store or the washing zone. The low water absorption of XPS is advantageous under such conditions, but it will not repair a cracked coating or a leaking drain. Water should be controlled by the floor layers intended for that purpose. The choice of thermal insulation does not relieve the designer of the need to design seals and connections at the drainage points.
The chemical resistance of the entire system is also important. The preparation used to clean the floor usually comes into contact with its surface, but if there is damage it may reach deeper. XPS is not resistant to every solvent. Before installation, the compatibility of adhesives and coatings with polystyrene must be checked. In the event of a leak of process substances, the assessment is carried out for the actual composition, not for the general name of the agent.
A good order includes the conditions of use
XPS is produced by, among others, Synthos, Austrotherm and Ravago. A comparison of offers should concern the same thickness and the set of required parameters. A commercial description of styrodur does not allow an assessment of performance under pallet truck traffic. In the specification it is worth recording the intended application and the documents needed by the designer, including data on deformation and moisture.
Before acceptance of the works, the continuity of the XPS, its support and the position of the installations are checked. It is worth recording the layout of the boards before the load-bearing layer is executed. The extruded polystyrene will later be invisible, and a repair would require dismantling the floor. The highest number on the packaging is therefore not what proves the quality of the decision. What proves it is the conformity of the material with the load, the floor construction and the way the hall is used.