Thermano Roof in the roof assembly. Fixing, covering and support
At a glance
Thermano Roof can be used in various roof assemblies, but each has its own rules. A bonded assembly requires a different assessment of the joints than a mechanically fixed one. The board’s parameters are part of the selection, alongside the compatibility of the covering and the preparation of the substrate. Thermano Roof is a rigid PIR board with a gas-tight multilayer aluminium facing on both sides. The manufacturer specifies it for, among other things, flat roofs and above-rafter insulation. When selecting PIR boards for an assembly, draw the pitched roof slope on which the insulation is to sit above the wooden rafters in the actual cross-section. The Thermano Roof layer above the rafters must be connected to the terminations at the eaves and openings, because the remaining layers must fit the same solution.

The role of the facing and the other layers
The individual layers must work together, because above-rafter thermal insulation also affects the position of the roof covering relative to the eaves and windows. The adopted assembly should allow the attic space to be retained while at the same time designing the new height of the roof slope. Add the roof geometry, the timber layout and the locations requiring adjustment of existing flashings to the description of the solution so that the complete set of layers can be verified.
Fastening matched to the substrate
The external format of the board is 1200 × 2400 mm, and the edges can be made as BASIC, TOP or MASTER. The edge variant affects the way adjacent boards are laid, so it must be determined before planning the division of the roof slope.
Continuous polyurethane insulation requires a correct detail; in the description, include the arrangement of the large boards at the ridge, valley or row of roof windows. The cutting lines of the large boards must be planned taking into account the support at windows and valleys, before the layout is considered ready for execution. The instructions for the full field do not cover all terminations, because an excess of small elements at the opening makes it difficult to create a stable and tight connection. The installation drawing should allow the cutting lines to be planned before bringing material onto the sloping surface. Before accepting a substitute, check the width of the supported cut-offs, the position of the joints and the window frame solution in relation to the adjacent layers.
When Thermano Roof is used above the rafters, the fastening must connect the layers above the insulation to the structure. The board does not independently take over the entire task of the fasteners. The design must show how loads are transferred through the system to the timber. In parallel, the water-draining layer is installed. These are two different tasks that meet in one cross-section and require mutual coordination.
Compatibility of the protective layers
The gas-tight facing limits the flow of vapour through the board itself, but does not seal the contact with the water-draining layer or the penetrations through the roof slope. Therefore, water drainage and protection at the penetration points require a separate detail that is consistent with the board.
When selecting the protective layers, discuss the junction between the gas-tight boards and the layer responsible for draining water from the roof slope. The drainage layer must be installed in accordance with the detail at every intersection of the roof slope, because tightness must also be achieved at the connections between different parts of the system. In the finished building envelope, the polyurethane foam needs a covering, because the sealed aluminium surface does not automatically close the perimeter of the chimney or window. The adopted detail must allow the function of thermal insulation to be separated from the function of the layer protecting against precipitation. In the description of the installation sequence, indicate the route of the water layer, the sealing of the penetration and the possibility of safely completing the day’s stage; this information should be consistent with the documentation for the entire set.
Thermal effect of the entire building envelope
For Thermano Roof, a lambda of 0.023 W/(m·K) is declared, while at the same time the board is described as having enhanced mechanical parameters. Both groups of properties must be considered together in the roof system, without substituting one for the other.
In the calculation of the system, take into account the simultaneous requirement of limiting heat loss and achieving mechanical properties. The thickness of Roof must be calculated using its lambda of 0.023 regardless of the stated mechanical parameters, so as not to combine parameters originating from different material variants. A mere change of material name does not provide equivalence, since a higher mechanical parameter does not automatically reduce the amount of heat conducted through the board. When comparing polyurethane boards in alternative systems, the variant meeting both requirements must be selected without substituting one parameter for the other. In both variants, compare the result of the R calculation and the separate load and fixing conditions for the roof layers with the same function of the building envelope.
Range of mechanical and fire parameters
The covering and installations transfer loads to the Thermano Roof system, whose support and fasteners must be calculated as a whole. The board documentation states a minimum of 200 kPa in the test at 10% deformation and TR100. Neither CS200 nor TR100 on its own determines the permissible weight of the equipment. For the fire assessment, note the product’s reaction to fire E separately and check the requirements for the complete roof.
The schedule of requirements for the assembly should explain the loads transmitted by the covering and installations to the layers above the roof structure. The CS200 and TR100 parameters must be related to the relevant actions in the designed assembly, and the scope of assessment must correspond to the actual configuration of the building envelope. The significance of the parameters changes with the scope of assessment, because none of these figures is a ready-made value for the permissible weight of equipment on the roof. Before approving the structure, the support and fixing assembly must be selected on the basis of calculations for the entire solution. In the application documents, find the method by which forces are transmitted to the structure and the conformity of the solution with the required fire rating, and compare them with the designed layers.
Purchase in line with the adopted system
If the roof is to be used with installations, describe the planned loads and the method of supporting Thermano Roof already at the purchasing stage. This will make it possible to link the selection of boards and fasteners to the actual transmission of forces to the structure and to the required fire rating of the assembly.
When pricing the item “polyurethane insulation”, analyse the scope of changes at the eaves resulting from adding thermal insulation above the rafters. The costs must include flashings that require adaptation after the roof layers have been raised, so that the scope of purchase corresponds to the complete specification of the solution. An omitted item may come back as additional work, because leaving the same flashing may be impossible after the height of the entire assembly has changed. A well-described scope makes it possible to include the saved attic space together with the cost of adapting the roof on the outside. When accepting the delivery and the works, confirm the measured quantities of boards, fasteners, flashings and works at windows and roof-slope terminations, so that they match the agreed system.