PIR insulation
swissporPIR Alu performance and the design of a complete building assembly
At a glance
swissporPIR Alu is a thermal insulation board with a rigid polyisocyanurate foam core and a gas-tight laminate containing aluminium, paper and polyethylene on both sides. Its parameters relate to a specific construction and thickness of the product. In a roof or wall, it must be combined with a suitable substrate, fixing and protection against water. The laminate is not the steel facing of a structural sandwich panel, nor is it a finished covering. The guide explains the relationship between the lambda value, the board’s thermal resistance and the result for the entire building assembly, as well as the selection of formats, joints and scope of delivery. The broader term “polyurethane insulation” does not replace the full designation of this PIR product.

swissporPIR Alu PIR boards and the role of the facing
On the cross-section of swissporPIR Alu, indicate the support and the protection and finish on both sides of the insulation. The silver surface does not give it the function of a load-bearing panel. The position of the board in the assembly results from the division of tasks among all layers.
Selecting the thickness for the required resistance
For swissporPIR Alu, the declared lambda is 0.022 W/(m·K). The thermal resistance R_D increases with thickness: 100 mm corresponds to 4.50 m²K/W, 120 mm — 5.45, and 160 mm — 7.25. The data must be assigned to the correct delivery item.
With the lambda of swissporPIR Alu at 0.022, select the thickness taking into account the height of the entire cross-section. The R_D of the insulation remains a different quantity from the U-value of the roof or wall. Comparing variants requires the data for each board and a separate calculation of the complete assembly.
Polyurethane insulation in the right format
Select the format of swissporPIR Alu from the variants 1200 × 600 mm or 2400 × 1200 mm, and the thickness from the specified range of 20–300 mm. Every listing requires confirmation of availability. Where there are numerous cut pieces, also mark the profile of the ordered edge on the drawing.
A larger format of swissporPIR Alu does not always mean less waste. The cutting plan should preserve the terminations and continuity of joints around obstacles. Check the covering area and the availability of the specific combination of dimensions before you take the number of boards based on the plan view.
Continuity at three-dimensional junctions
At the edges and at service penetrations, the swissporPIR Alu layer changes geometry. The connection to the adjacent building element can increase heat losses, which is why the parameters of the regular field should not be transferred to the entire perimeter.
A spatial connection of the insulation requires a drawing of the edge, the service penetration or the change of direction of the layer. A greater thickness of swissporPIR Alu in the middle does not make up for the missing fragment at the edge. Agree the sequence of execution and the compatibility of the materials that are to come into contact there.
CS, creep and service loads
For swissporPIR Alu, check the mechanical parameters separately: CS minimum 150 kPa and the creep designation CC(2/1.5/50)25. The reaction to fire of the product is class E, which does not mean non-combustibility. All data must correspond to the variant adopted in the system.
For swissporPIR Alu, distinguish CS from creep under sustained long-term pressure: the results relate to different conditions and are not interchangeable limits. Link the mechanical selection to the duration of the load. Separately, compare the product’s reaction to fire class E with the fire classification of the assembly actually being designed.
Polyurethane insulation: material cost and cost of the whole system
Before comparing prices for swissporPIR Alu, thickness, edge profile and usable area must be standardised. Drawing out the cut pieces allows the allowance appropriate to the given assembly to be calculated instead of adopting it solely from the surface area.
In the swissporPIR Alu offer, list the full designations, the quantities after cutting, and the work on details. A lower price per metre may cover a different thermal resistance or a smaller scope of supply. The point of comparison should be the same completed state of the assembly.
A case worth considering
In a system with swissporPIR Alu, low thermal conductivity works together with correct joints and protection against water; the laminate does not perform these tasks on its own. The choice of adhesive or fixing relates to the specific substrate and instructions. The fire requirements of the entire roof covering remain separate. Bringing this information together allows a complete assembly with predictable performance to be selected.