termPIR MAX 19 AL in roof design: thermal performance, geometry and loads

At a glance

In a roof, thermal insulation cannot be separated from the parapet height and the drainage layout. termPIR MAX 19 AL can help to reconcile these requirements. At the same time, the fixing and the permissible loads of the entire building envelope must be fully verified. termPIR MAX 19 AL is a board made of rigid PIR foam, protected on both sides with a gas-tight laminate of aluminium, paper and polyethylene. Its key distinguishing feature is its level of thermal conductivity. When selecting PIR boards for the assembly, draw the point at which little space remains for the insulation under the existing flashing in the actual cross-section. The cross-section at the existing flashing must be checked before taking advantage of the low lambda value, because the remaining layers must fit the same solution.

White face and pale profiled edge, accompanying the termPIR MAX 19 AL guide

Role of the facing and the other layers

The individual layers must work together, because a very low lambda does not remove the constraints relating to the substrate and the adjacent layers. The chosen set should allow the advantage of the thickness to be exploited where it genuinely simplifies the detail. Add the available section height and the scope of work required to increase it to the description of the solution, so that the complete set of layers can be verified.

Support and method of connection

The FIT variant has a straight edge, LAP an overlap, and TAG a tongue and groove. The choice of geometry for termPIR MAX 19 AL is linked to the arrangement of the joints in the given roof detail, so it must be specified before the boards are scheduled.

Continuous polyurethane insulation requires a correct detail; in the description, include the joint of the boards with the rebate where the substrate shows a slight unevenness. The profiled edges must be fitted together without forcing the boards to lie over an uneven substrate, before the layout is considered ready for execution. The instructions for the full field do not cover all terminations, because the TAG profile alone neither levels the structure nor closes every imprecise joint. The installation drawing should allow a flat support to be prepared before the tightness of the laid thermal insulation is assessed. Before you accept a substitute, check the condition of the edge, the support under the joint and the actual width of any gap in relation to the adjacent layers.

Changing the insulation to termPIR MAX 19 AL may reduce the required thickness, but it should trigger a check of the entire cross-section. The lengths of the fasteners and the position of the layers relative to adjacent elements must be checked. All dimensions developed for another board should not automatically be retained. CS100 requires a separate check. A substitute is a technical solution only when the remaining elements still fulfil their functions.

Air, vapour and water tightness

Until it is built in, termPIR MAX 19 AL requires protection against damage to the facing. The gas-tight laminate limits vapour transmission through the plane of the board, but it does not seal the joints and perimeters by itself.

When selecting the protective layers, discuss the point where services are led out at the perimeter of the layer with the gas-tight facing. The perimeter of the laminate must be connected to the intended wall or service penetration seal, because airtightness must also be achieved at the joints between different parts of the system. In the finished building element, the polyurethane foam needs protection, because even a very good thermal parameter does not compensate for an open path for air flow. The adopted detail must allow the critical perimeter to be closed without relying solely on the metallised surface of the board. In the description of the installation sequence, indicate the continuity of sealing and the protection of the material during the interval between work stages; this information should be consistent with the documentation for the entire set.

Thickness matched to the assembly

For termPIR MAX 19 AL, the declared lambda is 0.019 W/(m·K) at thicknesses of 80–220 mm. When the required resistance remains the same, a lower lambda translates into a thinner insulation layer in the roof cross-section.

In the system calculation, include the layers compared at the assumed resistance of 5.0 m²K/W in the calculation example. The calculated thickness of termPIR MAX 19 AL must be matched to the variant available in the actual delivery so as not to combine parameters from different material variants. A mere change of material name does not produce equivalence, since the product of R and lambda gives a theoretical thickness that need not occur in the delivery. When comparing polyurethane boards in alternative arrangements, the nearest suitable thickness must be selected without promising a U-value result on the basis of the foam alone. In both variants, compare the result of the layer calculation and the re-checking of the entire building element after product selection for the same function of the building element.

Range of mechanical and fire parameters

In the specification for termPIR MAX 19 AL, CS(10/Y)100 and reaction-to-fire class E must be entered as characteristics of this product. A mere similarity of facing does not allow these declarations to be transferred from another board.

The schedule of requirements for the system should clarify the CS(10/Y)100 declaration belonging to termPIR MAX 19 AL and not to a similar board. The CS100 declaration must be verified independently of the benefit resulting from the lambda of 0.019, and the scope of assessment must correspond to the actual configuration of the building envelope. The significance of the parameters changes with the scope of assessment, because better thermal insulation does not automatically mean greater load resistance. Before approving the structure, the serviceability requirements must be checked independently of the expected reduction in thickness. In the application documents, look for conformity of CS and class E with the documentation of precisely this ordered product and compare them with the designed layers.

Complete specification for pricing

termPIR MAX 19 AL boards are available in formats 600 × 1200 and 1200 × 2400 mm; for the rebate, allow for the coverage correction. Begin the comparison of offers by balancing the thermal effect.

When pricing the item “polyurethane insulation”, analyse the cost difference between thinner insulation and rebuilding the elements surrounding it. The two cost variants should provide the same thermal effect and the same service function, so that the scope of purchase corresponds to the complete specification of the solution. An omitted item can come back as additional work, because a more expensive square metre of board can only be justified by a specific benefit in the whole task. A well-described scope allows the material price to be separated from the cost of changes to geometry, fixing and finishing. At the acceptance of the delivery and the works, confirm two complete calculations together with the cutting plan and the effects of the adopted layer height, so that they match the agreed system.

7 branches. Materials closer to your project.

Sandwich-panel.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project