Thermano Compact at roof insulation terminations. Selection and cutting

At a glance

At a parapet, roof edge or roof transition, a large board often has to be cut. Thermano Compact can make it easier to fit the insulation. At such a location, the rules for support, airtightness and fixing arising from the adopted roof solution still apply. Thermano Compact is a PIR board in the 600 × 1200 mm format, with a multi-layer facing containing aluminium. The smaller format is an important practical feature. When selecting PIR boards for the assembly, draw a small working area into which a 600 × 1200 mm board can be brought more easily in the actual cross-section. The Thermano Compact format must be matched to the size of the working area and the available transport route, because the remaining layers must fit the same solution.

Rectangular white casing with a round opening and visible layers, accompanying the Thermano Compact guide

Product construction in the context of the system

The individual layers must work together, because the convenient handling of a smaller board does not guarantee that the entire installation is correct. The chosen set should make it possible to organise the work on a short section without abandoning the design of layers and joints. Add the dimensions of the installation location, the access width and the planned position of each joint to the description of the solution so that the complete set of layers can be verified.

Fixing matched to the substrate

The BASIC and TOP variants differ in the way they are joined, so when cutting an infill piece, plan a new joint before you deprive the board of the tongue-and-groove profile on one edge.

Continuous polyurethane insulation requires a correct detail; in the description, include the cut piece taken from a TOP board, which loses part of its factory overlap once shortened. After cutting a TOP board, the joint between the retained tongue-and-groove profile and the new straight edge must be planned before the layout is considered ready for execution. The instructions for the full field do not cover all terminations, because using offcuts requires providing support and properly closing the new joint. The installation drawing should make it possible to select the cutting method according to the actual direction in which successive pieces are laid. Before you accept a substitute, check the position of the tongue-and-groove profile on every element used and the stability of the resulting strip at the perimeter in relation to the adjacent layers.

If Thermano Compact completes a small section of a larger layer, both of its terminations become important. The small insert must work together with the material on both sides. Matching the width alone does not determine tightness or stability. At the cut edge, a method of connection suited to that location must be provided for. It should not be assumed that the cut piece has retained the geometric properties of a full TOP board.

Compatibility of the protective layers

The aluminium facing does not replace moisture protection: at a window, wall or substrate, tightness depends on flashings and joints, not on the board alone.

When selecting the protective layers, discuss the connection of the small PIR insert to the substrate and to the flashing at the location exposed to water. The covering of a small section of insulation must also include its connections to the surrounding material, because tightness must also be achieved at the joints between the different parts of the system. In the completed building element, the polyurethane foam needs a covering, because the facing surface may be undamaged and water can still penetrate through an unclosed side. The adopted detail must allow the detail to be covered together with its terminations instead of protecting only the middle of the board. In the description of the installation sequence, indicate the method of water drainage, the condition of the flashing and the connection of materials on all sides of the insert; this information should be consistent with the documentation for the entire assembly.

Thermal effect of the entire building envelope

Lambda 0.023 W/(m·K) describes heat conduction through Thermano Compact; select the thickness according to the required thermal resistance and the location within the detail.

In the system calculation, include the narrow strip of insulation whose thickness is limited by the existing building detail. The thermal resistance of the small insert should be assessed together with the geometry of the materials surrounding this section, so as not to combine parameters from different material variants. A change of material name alone does not produce equivalence, since the influence of the narrow strip on the thermal bridge also depends on the geometry of the materials around it. When comparing polyurethane boards in alternative arrangements, assess the benefit of insulating the detail without transferring the R result to the entire junction. In both variants, compare the width and thickness of the insert and the continuity of the thermal insulation in the adjacent sections for the same function of the building element.

Range of mechanical and fire parameters

Cutting Thermano Compact does not change the assignment of the compression parameter to the product thickness. For boards up to 30 mm, the declared minimum at 10% deformation is 150 kPa, and from 40 mm — 200 kPa. A test described in this way does not determine the load-bearing capacity of the finished insulation termination. A separate property is the reaction to fire E; PIR does not thereby become a non-combustible material.

The schedule of requirements for the system should explain the difference between the declared CS150 up to 30 mm and CS200 from 40 mm. The CS value for Thermano Compact must be assigned to the thickness shown on the board marking, and the scope of assessment must correspond to the actual configuration of the partition. The meaning of the parameters changes with the scope of assessment, because the appearance of two boards does not show which declaration range each of them belongs to. Before approving the structure, the pressure on the detail should be assessed while retaining the data of the precisely selected variant. In the application documents, find the thickness on the label, the bearing area and the way the anticipated load is distributed, and compare them with the designed layers.

Complete specification for pricing

Determine the number of Thermano Compact boards from the cutting plan, not from the area of the recesses. A narrow offcut from one end detail may not find a place in the next detail.

When pricing the item “polyurethane insulation”, analyse the set of several small pieces whose combined metreage does not show the number of full boards. It is worth arranging all the necessary cut pieces on the 600 × 1200 mm format before purchasing the packs, so that the scope of purchase corresponds to the complete specification of the solution. An omitted item may come back as additional work, because narrow remnants may not fit the next location despite the material thickness being the same. A well-described scope allows waste to be limited by matching the cutting plan to the actual shapes of the required elements. At the acceptance of the delivery and the works, confirm the cutting sketch, the number of full boards and the possibility of safely using the remaining fragments, so that they agree with the agreed system.

7 branches. Materials closer to your project.

Sandwich-panel.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote

Materials for your project