BauderPIR M/MF with mineral facing in the roof system

At a glance

The M/MF board is to remain in the system with a mineral surface beneath the covering. A proposed replacement with aluminium changes the contact layer, even if both cores are PIR. The assessment should cover adhesion, fixing and thermal data. Changing a single name in the schedule is not a sufficient system update. The cross-section under consideration comprises a roof with a PIR board with a mineral facing. The BauderPIR M/MF task must be described together with the layers adjoining its surface. An important junction point is the area of the fleece beneath the waterproofing layer. Before selecting materials, the thickness of the insulation to be ordered and the condition of the substrate beneath the covering must be established so that the sequence of layers has a real reference.

Matt facing and pale insulation core, illustration for the BauderPIR M/MF guide

Function of the board in the cross-section

A correct assembly should allow the correct lambda and a compatible connection with the covering to be established. The functions of the other layers must be defined separately.

The correct product and the scope of its data

In an assembly with BauderPIR M/MF, the covering layer is in contact with the mineral fleece laid on the PIR core. The fleece is present on both sides of the board, and the M and MF variants differ in their edge; the format is 1200 × 600 mm. The Polish data sheet for M assigns λD 0.026 W/(m·K) to thicknesses from 80 mm to below 120 mm. Do not replace this with the value 0.022 merely because the board being compared also has a PIR core. A minimum of 120 kPa in the compression test and reaction-to-fire class E describe the product with facings, whose connection with the covering must be assessed separately.

Scope of the example comparison

BauderPIR M/MF with an example thickness of 100 mm and a lambda of 0.026 gives approximately 3.85 m²K/W in the d/λ calculation. A comparative material with a conventional lambda of 0.040 would require approximately 153.8 mm; the calculation does not declare its properties or the RD of the selected product. Before covering M/MF, checking for an even substrate and undamaged fleece remains more important than the mere compatibility of resistances. Also check the straight edge of M or the milled edge of MF and the compatibility of the facing with the method of fixing the covering. Only such a set of checks applies to the entire solution.

The calculation involving BauderPIR M/MF describes the stated quantity, not automatically the class of the entire system. The relevant assumption is the lambda dependent on the thickness of the M variant. The result must be compared with the limitation defined as the condition for compatibility of the mineral facing with the adopted system. With reference to this section, the correct thickness range must be read in the document for the variant being ordered. A set of documents for the specific thickness of M or MF and the connection with the covering, from which the position of each layer follows, is helpful. Only then can a waterproofing covering compatible with the mineral facing be considered without automatically transferring principles from another combination of materials.

How to assess the proposed change

The variant based on the decision to retain the designed facing and select the required thickness must be considered through the full section. In the second step, the action must be considered: changing the entire confirmed assembly after re-comparison. With BauderPIR M/MF, both proposals must preserve the requirements at the location described as the fleece area beneath the waterproofing layer. Recalculation of the board with mineral facing using the lambda of the aluminium variant must be excluded, because such a simplification changes the basis of comparison. The final scope should be confirmed by the specialist approving the compatibility of the insulation with the covering. For the selected solution, a schedule of parameters is needed covering thickness, facing and edge, consistent with the materials located directly below and above the insulation.

Surface and joint finish

The surface of BauderPIR M/MF is a matt mineral fleece. Its type must be taken into account when selecting the layer with which it will work. In the documentation, the straight profile in M or the milled profile in MF must also be identified, instead of replacing the actual geometry with a general symbol. Acceptance should be based on the description of the fleece on both surfaces and the correct edge profile. For this reason, the waterproofing covering compatible with the mineral facing should only be installed after an agreed inspection. In the drawing, it is worth highlighting the fleece area beneath the waterproofing layer, because that is where the course of the joint changes.

The sequence of works follows from the layout

Before laying BauderPIR M/MF, a level substrate beneath the board with undamaged fleece must be ensured. The schedule should include inspection of the element described as the fleece area beneath the waterproofing layer. For acceptance, a set of documents for the specific thickness of M or MF and the connection to the covering must be prepared, indicating any execution changes. After this inspection, work can proceed to the scope that is the waterproofing covering compatible with the mineral facing. The coordination of the sequence should be led by the specialist approving the compatibility of the insulation with the covering, especially when different layers are carried out by different teams. This allows the tasks of the polyurethane insulation to be separated from the work providing the other functions of the section.

Specification ready for pricing

The enquiry for BauderPIR M/MF should clearly indicate a roof with PIR board in mineral facing. The description must be accompanied by a schedule of parameters covering thickness, facing and edge, so that the supplier knows the adopted variant. A separate item may be the work needed to determine the correct lambda and the compatible connection to the covering. It is worth requesting a breakdown of changes caused by any replacement of facing or geometry. Each such proposal should again take into account the condition of compatibility of the mineral facing with the adopted system. After selecting the solution, the description of the fleece on both surfaces and the correct edge profile must be retained as the basis for identifying the material on site. In such an order, polyurethane boards are part of a specific system, not a category of freely interchangeable sheets.

7 branches. Materials closer to your project.

Sandwich-panel.pl map of seven branches offering sandwich panels, PIR boards and sheet metal
  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]

Check prices and availability: +48 500 409 109

Free quote