Positioning doors and windows in a steel building before detailing the openings

On a drawing, it is easy to shift a gate by a few metres. In the finished building, however, a column may stand in that spot or a bracing may run through it. The same applies to windows. Openings in a steel hall must be planned together with the structure and the envelope. The best moment comes before the elements are ordered. Then the layout can be matched to the company's operations without demolishing walls and looking for costly alternative solutions. Vehicle dimensions do not always determine the required opening. The transported load may protrude, and a machine's attachment may be wider than its cab. Also check the turning conditions in front of the gate. A steel hall should allow entry in the real layout of the yard. A wide opening helps little if the vehicle cannot line up with it straight on.

By |2026-11-15T03:32:23+01:002025-02-27|Construction basics|Comments Off on Positioning doors and windows in a steel building before detailing the openings

Utherm Sarking LE Plus: PIR and membrane in a roof assembly

The factory-bonded combination of the membrane with Utherm Sarking LE Plus simplifies part of the build-up above the rafters. However, it does not complete the connections at windows, at the eaves and at service penetrations. A consistent system requires defining both these locations and the airtightness on the attic side. Utherm Sarking LE Plus is one of the PIR boards for pitched roofs. On both sides it has a multi-layer gas-tight laminate. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. The PIR boards should be shown in a section that explains the difference between Utherm Sarking LE and the LE Plus variant with the additional membrane. When selecting the layers, the full name of the Sarking variant must be established before choosing additional membranes.

By |2026-11-16T01:37:02+01:002025-02-27|Construction basics|Comments Off on Utherm Sarking LE Plus: PIR and membrane in a roof assembly

XPS in industrial facilities: service temperature considerations

In an industrial plant, the air temperature is often moderate, yet hot surfaces occur locally. This applies to pipes, equipment housings and zones of the technological process. XPS may only be used under the conditions permitted for the specific product. Extruded polystyrene is not a universal high-temperature insulation. Its suitability is determined by the temperature of the board itself and by the other influences that occur during plant operation. It is worth distinguishing between general and local conditions. A measurement in the middle of the room does not describe what happens behind a hot housing or next to a pipe. XPS may be exposed to heat conduction through an adjacent component, to radiation and to heating from the air.

By |2026-11-16T06:07:33+01:002025-02-21|Construction basics|Comments Off on XPS in industrial facilities: service temperature considerations

Why wall panels and roof panels differ on a steel building

The façade panel is often almost smooth, whereas the roof panel has a pronounced profile. The difference is not just a matter of appearance. The roof and walls of a steel hall work under different conditions. They drain water differently and require different connections. That is why a similar colour and the same core thickness do not make two panels interchangeable. The order must specify the place of use for each element. A roof panel is supported on purlins or other supports specified in the design. It carries the loads assumed for that roof, including snow and wind actions. The span between supports, the method of fixing and the way the panel works structurally all matter. Parameters are selected from the product documentation, not by comparing thickness alone.

By |2026-11-15T03:32:04+01:002025-02-20|Construction basics|Comments Off on Why wall panels and roof panels differ on a steel building

Specifying a protective coating for sheet metal exposed to the weather

Describe the conditions on both faces of the sheet before choosing a finish. Outside, note whether the site is coastal, close to heavy traffic or other pollution, or surrounded by dense vegetation. How long does the surface stay wet? Inside, check for condensation and consider what the building is used for. The two faces may need different protection. Give the person specifying the coating these details so they can confirm where the proposed product can be used. Colour and warranty length alone tell you little about its suitability for that exposure.

By |2026-11-15T03:31:20+01:002025-02-18|Construction basics|Comments Off on Specifying a protective coating for sheet metal exposed to the weather

Metal picket fencing beside a garage: coordinating the driveway and boundary

At a house with a garage, the fence must work together with vehicle movement. The gate, the pedestrian gate, the posts and the pickets form a single frontage, but each of these elements serves a different function. Metal fence pickets can visually connect the driveway with the fixed fence bays. This does not mean, however, that identical fixing is used everywhere. It is worth drawing out the entire entrance zone before buying the infill. This makes it easier to keep good proportions and reduces collisions during everyday use. Check the width of the driveway, the position of the gate and the space needed for manoeuvring. Differences in driveway levels also matter. With a swing leaf, the area of its movement must be taken into account. With a sliding leaf, suitable space is needed along the fence. Detailed requirements follow from the gate design. The chosen picket spacing must not later force a change to a proven driveway geometry.

By |2026-11-15T18:26:25+01:002025-02-13|Construction basics|Comments Off on Metal picket fencing beside a garage: coordinating the driveway and boundary

Selecting cold-formed steel supports for sandwich panels

The sandwich panel and its support must be structurally compatible. It is not enough to choose the core thickness and space the steel at equal intervals. Cold-formed profiles carry the loads from the cladding, and their flanges provide the bearing and fixing surface for the panels. Span, direction of installation, wind, and the method of connection to the frame all matter. Z-sections, C-sections, sigma profiles and omega profiles have different tasks in this arrangement. It is worth distinguishing between them before ordering materials. On the elevation drawing, the direction in which the panels are laid and the position of their ends must be established. Vertical wall panels usually bear on horizontal rails. With a horizontal layout, suitably arranged vertical supports are needed. Every solution must comply with the documentation of the selected cladding. An aesthetically pleasing facade division alone does not determine safe spacing between supports.

By |2026-11-15T03:32:44+01:002025-02-08|Construction basics|Comments Off on Selecting cold-formed steel supports for sandwich panels

First grade or outlet: how to choose the right panel for the place of use?

In a commercial premises, the wall by the entrance and the back-of-house partition serve different roles, even though they may have similar dimensions. The choice between first grade and outlet should take these roles into account, as well as the condition of the specific panel. A reduced price does not describe the type of deviation. Appearance, installation and confirmed properties must be assessed separately. On a façade visible from the pavement, a consistent shade, gloss and regularity of joints will be important. In an enclosed dry storage area, a minor aesthetic blemish may matter less. This does not, however, mean technical freedom in the back-of-house. Requirements for load-bearing capacity, thermal insulation and fire protection derive from the function and the design.

By |2026-11-14T12:35:57+01:002025-02-02|Construction basics|Comments Off on First grade or outlet: how to choose the right panel for the place of use?

How to insulate a loft to reduce heat loss

Insulating a loft begins with deciding which areas will be heated and which will stay cold. The thermal boundary must be continuous and airtight, and its route is best marked on a house section. With usable slopes, insulation covers the roof, dwarf walls and every junction with the storey below. Watch stairs, the hatch and spaces behind dwarf walls, where leaks easily form. Use solutions that meet standards, such as those for thermal insulation, and take care when working on the roof.

By |2026-11-14T19:54:34+01:002025-02-02|Construction basics|Comments Off on How to insulate a loft to reduce heat loss

How to plan cutting sandwich panels without damaging the facings?

A good cut begins before the tool is started. You need to know why the opening is being made, how the element will be supported and how the edge will be closed. In a sandwich panel, two steel sheets and the core work together. An accidental cut can therefore change the load-bearing capacity, airtightness and durability, even when the line looks straight. Shortening a panel to the agreed length and making an opening for a window are different tasks. An opening removes part of the cross-section and changes the flow of forces. Its size, position relative to the supports and distance from the edge must be assessed for the specific system. There is no single safe size for all products.

By |2026-11-14T10:17:29+01:002025-01-25|Construction basics|Comments Off on How to plan cutting sandwich panels without damaging the facings?