Building basics2026-11-15T18:16:21+01:00

Choose a product group

Metal roofing

Sandwich panels

PIR insulation boards

XPS

Accessories

Fencing

Building basics

Sandwich-panel.pl explains the basics of choosing sandwich panels, PIR insulation boards and metal roofing. Learn how the core differs from the facings, what the thickness describes and how the sheet dimensions relate to the effective cover area. The guides are intended for people planning a garage, industrial building, workshop or farm building. They explain which details to collect before ordering, how to identify accessories and what to inspect when the goods arrive. Use the articles to compare materials and prepare the questions that need to be resolved for your project.

Utherm Wall LE boards as part of a cavity wall

In a cavity wall, Utherm Wall LE is one component of a system in which several elements perform distinct tasks. The thermal insulation works together with the masonry, the wall ties and the protection against water. A good cross-section shows the role of each element and how the detail is finished at openings and at the base of the wall. Utherm Wall LE is a PIR board with a gas-tight laminate on both faces. The manufacturer describes it as a solution for cavity walls. The terms “polyurethane boards” and “polyurethane foam” are broader than the precise designation of the PIR product. PIR boards should be shown in a cross-section that explains the intended use of Utherm Wall LE for the insulation layer of a cavity wall. When selecting the layers, a distinction must be made between Wall LE with a laminate and the product combined with a gypsum facing.

Insulating the floor above a garage without overlooking the edges

Insulating the ceiling above a cold garage should cover not only its centre but also the junctions with the walls and the edges. EPS can perform in a suitably designed floor or in an approved arrangement from below. Choosing where to place the insulation requires checking heights, loads and fire requirements. The thinnest detail can weaken the effect of the entire surface. First, it is necessary to determine which rooms are heated and what conditions prevail in the garage. A ceiling between a warm room and a cold space requires a different assessment than a ceiling between two similarly heated interiors. In a garage, the temperature depends, among other things, on ventilation and on the garage door being opened. It should not automatically be assumed that it constantly matches the outdoor temperature.

α-therm SARKING: choosing roof layers with IDELCO insulation

IDELCO α-therm SARKING is used to insulate pitched roofs above the rafters. The PIR board has a multi-layer aluminium laminate on both sides and a tongue-and-groove profile on all four edges. However, it does not include a factory-applied membrane with laps: the underlay is selected separately. The roof cross-section must combine continuity of the thermal insulation with support, fixing of the counter-battens and drainage at the eaves. Laying it over the timber reduces gaps in the primary insulation layer, but does not eliminate all thermal bridges. In this article we discuss junctions with the wall, flashings and openings, as well as the effect of the new layers on the height of the roof slope. The name “polyurethane insulation” does not describe these installation solutions.

What frame should be prepared for walls made of panels with a mineral wool core?

A level façade starts with a properly prepared frame. A panel with a mineral wool core transfers loads through a specific arrangement of supports, but it does not correct a crooked structure. In a small workshop, doors, windows and equipment fixing points also matter. Planning these before installation avoids later cutting and adding random profiles. Loads acting on the panel are transferred through fasteners to rails or columns, and then to the main structure and foundations. Every connection along this path must be checked. A suitably thick panel alone does not solve the problem of a weak rail. It also does not replace bracing unless it has been designed for that function.

Choosing wall panel fixings to suit the supporting structure

The fastener for an insulated wall panel with a mineral wool core must hold the cladding and not damage its facings. Its length is only one of the pieces of information required. The type and thickness of the support, the wind load and the way forces are transferred through the joint also matter. Selection starts with the construction and ends with checking that the washer is correctly pressed. A thin steel purlin, a thicker profile and a reinforced concrete support require different solutions. In steel, the drill-through capability and the correct thread engagement are important. For concrete, suitably selected anchors and a suitable method of preparing the hole are used. A solution cannot be transferred between substrates solely because the screw has a matching length.

How does roof pitch affect the choice of insulated roof panels?

The term “flat roof” is sometimes used for several different solutions. A roof made of sandwich panels with a low pitch must still drain water across the profiled surface and the joints. It does not thereby become a flat roof with a continuous membrane. The permissible pitch is determined by the specific panel, the method of jointing and the geometry of the finished roof slope. In a panel roof, the outer steel skin together with the joints forms the covering. In another arrangement, the structure supports the insulation and a separate waterproof layer, for example a membrane. Both roofs may look almost flat from the street, but they handle drainage and weathertightness differently.