How should you plan the anchoring of a steel hall in a concrete foundation?
The column-to-foundation connection transfers forces from the hall to the substrate. A chemical anchor is one way of making such a fixing, but it must be selected to suit the concrete, the loads and the geometry of the base plate. There is no single rod or single hole depth suitable for all halls. The work begins with the design of the connection. The connection may be subject to tension, shear and bending moment. The condition of the concrete, the edge distances and the spacing between anchors also matter. The capacity of a single anchor from a table cannot simply be multiplied by the number of rods and taken as the capacity of the base. The group of fasteners acts together with the concrete and the base plate.