About PiVi

This author has not yet filled in any details.
So far PiVi has created 1593 blog entries.

T18 or T35 roofing sheets: how the profiles differ and which to choose

T18 and T35 differ primarily in the geometry of their cross-section. A taller profile may perform more favourably in a given support arrangement, but it does not offer a universal advantage in every situation. Selection requires checking loads and the data for the specific sheet. Dimensions hidden under the same nominal name may vary. The designation usually refers to the nominal height of the corrugation. The T18 family comprises lower trapezoidal profiles, while T35 has more pronounced ribs. However, the name is not a complete drawing of the product. Different cross-sections may have different flange widths, rib spacing and overall widths.

By |2026-11-14T16:28:38+01:002023-08-12|Construction basics|Comments Off on T18 or T35 roofing sheets: how the profiles differ and which to choose

What really determines the durability of an insulated wall panel with a mineral wool core?

It is not possible to assign a single service life to all mineral wool panels. A dry studio wall performs differently from cladding next to a wet driveway and a frequently washed service area. Durability is determined by the coatings, the joints and how the building is maintained. Regular inspection allows a small problem to be caught before it affects a larger section of the wall. A change in the shade of the steel sheet does not automatically mean a loss of load-bearing capacity. A worn seal does not necessarily require replacement of the entire panel. Appearance, the condition of the steel protection, the adhesion of the facings to the core and the tightness of the joints must be assessed separately. Each of these elements has different signs of ageing.

By |2026-11-14T10:15:38+01:002023-08-12|Construction basics|Comments Off on What really determines the durability of an insulated wall panel with a mineral wool core?

What to check before building a patio roof

Begin with how the terrace is used, because that determines the roof layout. Check that posts do not conflict with doors or the circulation route, and that the height at the wall allows the required fall and windows to open freely. Analyse the roof's effect on daylight in rooms and compare the structure's extent with the orientation of the sun. For wall fixing, establish whether the substrate can carry the loads rather than choosing anchor lengths by eye. Assess water runoff, rain noise and condensation separately.

By |2026-11-14T19:45:56+01:002023-08-11|Construction basics|Comments Off on What to check before building a patio roof

Omega sections in façade subframes: small profiles with an important role

Omegas have a characteristic cross-section resembling a hat. The central part is offset from the plane of the side flanges. This geometry is used in supporting frameworks and in substructure elements for walls and façades. Not every omega has the same function, however. Before choosing, it is necessary to establish what will be fixed to it and how the load will reach the building structure. A layout with two side flanges can make it easier to design the fixing to the substrate. The offset central part creates another working surface. The exact use of these sections depends on the chosen system and the orientation of the profile. It is not possible to impose a single scheme on all omegas.

By |2026-11-15T18:24:51+01:002023-08-03|Construction basics|Comments Off on Omega sections in façade subframes: small profiles with an important role

What to check before buying a 40 mm roof panel 13.5 m long?

A long roof panel can reduce the number of transverse joints. With a 13.5 m run, however, the benefit must be weighed against transport, lifting and thermal movement of the facings. The 40 mm variant in RAL 3009, especially when offered as second grade, should be checked for the specific batch. A long length does not mean a long span without supports. A 13.5 m panel may pass over several supports. The permissible spacing between them is determined by the load tables for the specific product, facings, colour and structural system. It cannot be assumed that because the run has been produced, it may be supported only at the ends. Such an assumption would change the way the entire building envelope performs.

By |2026-11-14T12:35:29+01:002023-07-30|Construction basics|Comments Off on What to check before buying a 40 mm roof panel 13.5 m long?

What is trapezoidal steel sheet T12 suitable for and how do you check its dimensions?

T12 is a low profile that does not dominate visually on a small building. It may suit the elevation of a back-of-house area or a light canopy. However, you must choose the right variant and check its performance on supports. The profile designation does not replace a cross-section drawing. Nor does it give a ready answer as to how large a spacing can be left between beams. It is a family of thin sheets with trapezoidal ribs. The designation refers to the nominal profile height, not the metal thickness. For example, a sheet 12 mm high may be made of steel 0.5–0.7 mm thick. The available range depends on the variant and coating.

By |2026-11-14T10:12:44+01:002023-07-27|Construction basics|Comments Off on What is trapezoidal steel sheet T12 suitable for and how do you check its dimensions?

IKO enertherm ALU: why the parameters must be related to the system

The system description with ALU should indicate the specific version of the board and how it is installed. A classification given for a specific steel substrate does not by definition cover every wall or floor. The scope of the document must be compared with the cross-section. Otherwise the bill of materials may look complete even though it is based on a test result that does not fit. The cross-section under consideration comprises the assembly of the building component with aluminium-faced PIR boards. The task of IKO enertherm ALU must be described together with the layers adjoining its surface. An important junction is the penetration of services through the continuous layer of thermal insulation.

By |2026-11-16T01:36:41+01:002023-07-25|Construction basics|Comments Off on IKO enertherm ALU: why the parameters must be related to the system

Cladding a steel building with insulated panels or single-skin sheets

The same steel structure can become a cool materials warehouse or a heated workshop. Much depends on the cladding, but it is not worth starting the choice with the price per square metre. First determine the conditions inside the building. Only then compare sandwich panels, single steel sheet and built-up cladding made of separate layers. Each solution has different tasks and requires appropriate details. If a steel hall is to be heated, it needs partitions with the right thermal insulation. This applies to the roof, walls, gates and connections to the ground. Thin steel sheet alone is not a thermal insulation layer. It can be part of a partition with additional insulation, but then the complete system must be assessed. The price of steel sheet does not describe the cost of such a wall.

By |2026-11-15T03:32:02+01:002023-07-24|Construction basics|Comments Off on Cladding a steel building with insulated panels or single-skin sheets

How to choose the length of sandwich panels for walls and roofs?

The longest available panel does not always produce the simplest building. On the wall, the vertical or horizontal layout, openings and the appearance of the façade matter. On the roof, the pitch, the length of the roof slope and any transverse joint are added. The order dimension should follow from the cladding drawing, not merely from a distance measured along the outer outline. Different panel families have different length restrictions. The ranges below show example product variants, not stock availability or the limits of all panels on the market.

By |2026-11-14T12:36:55+01:002023-07-21|Construction basics|Comments Off on How to choose the length of sandwich panels for walls and roofs?

Choosing metal roofing and wall cladding for a commercial building

First establish whether the building will be heated continuously, periodically or not at all, as this determines the choice of envelope. Also check the working temperature, humidity, substance emissions and the method of cleaning the interior. A dry warehouse, a workshop and a facility with frequent interior washing place different demands on the building envelope, and universal sheeting in an attractive colour need not withstand an aggressive environment. A sandwich panel combines facings with an insulating core and reduces the number of successive operations, but the benefit depends on preparation of the structure and delivery of components in the correct sequence.

By |2026-11-14T16:30:27+01:002023-07-18|Construction basics|Comments Off on Choosing metal roofing and wall cladding for a commercial building