Roofing over animal feed: keeping out rain, maintaining hygiene and ventilation

A feed shelter should limit water ingress and make it easier to keep things tidy. Corrugated fibre cement sheets can be used for this purpose if they suit the structure and the storage conditions. Asbestos-free fibre cement is worth choosing together with a solution for the eaves, ventilation and service penetrations. The sheet alone does not ensure storage quality. Bagged feed, loose material and stock stored in separate bays do not require an identical layout. The storage recommendations for the specific product also matter. The roof should make it possible to meet them, but it does not replace checking the condition of the material received. On the plan, it is worth marking the unloading points and the places where feed is taken daily. These are where rain is most easily blown in through open gates.

By |2026-11-15T18:28:59+01:002021-05-18|Construction basics|Comments Off on Roofing over animal feed: keeping out rain, maintaining hygiene and ventilation

PIR boards in a roof assembly: identifying the right type

PIR boards can perform an important thermal function in a roof, but they do not form it on their own. The choice of variant must be linked to the substrate, the waterproofing and the method of fixing. A cross-section through the entire assembly explains the most. It shows what task each layer has. Polyurethane foam can also mean a spray-applied material or an gap-filling foam. Spray application requires identifying the cell structure and the execution conditions. Foam for filling gaps performs a different function from a board. None of these materials should be regarded as a substitute solely on the basis of the word polyurethane. The rigid core is only one of the elements in assessing a roof board. Polyurethane foam restricts the flow of heat, but it does not automatically take over the function of the sheathing and the covering.

By |2026-11-16T01:34:22+01:002021-05-15|Construction basics|Comments Off on PIR boards in a roof assembly: identifying the right type

Checking a PIR quotation against the complete insulation system

Buying insulation can easily be reduced to the thickness and price of the board. In practice, however, correct performance is also determined by the materials at the interfaces between layers. A comparison with the complete assembly makes it possible to check whether the offer includes fixing, airtightness and the correct terminations. PIR boards may look similar yet have different facings, strength and intended use. Before purchase, a current technical data sheet, a declaration of performance and installation instructions are needed. A variant with a different facing may require a different adhesive. A substitute should be assessed together with the joint that will be made on its surface. The bill of materials should indicate the place of each variant in the assembly.

By |2026-11-16T01:34:49+01:002021-05-08|Construction basics|Comments Off on Checking a PIR quotation against the complete insulation system

Is standard EPS suitable for an inverted roof?

An ordinary EPS board described as suitable for roof and floor is not automatically suitable for an inverted roof. In such an arrangement the insulation lies above the waterproofing and may come into contact with water. A specific product intended for these conditions is required. However, this does not mean that every type of EPS is ruled out from the outset. In an inverted roof the waterproofing lies below the thermal insulation layer. The insulation and the subsequent layers protect it from some external influences. At the same time, the thermal insulation material is closer to rainwater. Rain can reach the spaces between the boards and the surface of the water-protection layer, depending on the system solution. These are different conditions from those beneath a sealed covering in a traditional roof.

By |2026-11-16T06:07:53+01:002021-04-15|Construction basics|Comments Off on Is standard EPS suitable for an inverted roof?

Combining PIR with cellulose or wood fibre: assessing the complete roof

More than one type of insulation can be used in a roof. PIR boards form a rigid layer, while cellulose or wood fibre can fill the designed spaces. Such a combination requires a deliberate choice of thermal layers, airtightness and the ability of the structure to dry out. Cellulose can be blown into prepared spaces. The layer above the structure and the infill between the rafters perform their task in different places. Their comparison should take into account the entire cross-section and the method of support. It is worth first identifying the layer that is to reduce the influence of the structural elements. Continuous PIR above the frame can perform a different task from a fibrous infill of the bays.

By |2026-11-16T01:34:29+01:002021-02-25|Construction basics|Comments Off on Combining PIR with cellulose or wood fibre: assessing the complete roof

A fibre cement roof over a grain store: its role in storage quality

The grain store covering should limit water ingress and allow the condition of the building to be monitored. Fibre cement sheets can be used in such a facility, but they do not replace the principles of grain storage. Asbestos-free fibre cement must be assessed together with ventilation, insulation and the organisation of loading and store operations. A dry roof surface is important, but it does not determine the conditions of the entire store. Moisture can come from the substrate, the walls and the grain itself when it is received. Temperature differences also matter. Therefore, when storage problems occur, it is not worth automatically blaming the covering alone. Before renovation, it is necessary to establish where and when dampness appears. Observations during rainfall and after cool nights help.

By |2026-11-15T18:28:57+01:002021-02-21|Construction basics|Comments Off on A fibre cement roof over a grain store: its role in storage quality

Recticel Eurothane Silver in a conventional warm roof: choosing the complete build-up

In a classic roof, the thermal insulation lies beneath the layer that protects against water. Eurothane Silver is intended for suitably selected roof systems. The specific method of fixing and the compatibility of the covering must be specified, rather than assuming that every combination is universal. Recticel Eurothane Silver is a PIR board with a multi-layer gas-tight foil on both sides and a printed grid. The current data sheet designates it for flat roofs in a classic assembly. When selecting PIR boards for an assembly, draw the classic flat roof for which mechanical fixing, bonding or ballast is being considered, in its actual cross-section. Eurothane Silver must be assigned to a specific mechanically fixed, bonded or ballasted assembly, because the other layers must match the same solution.

By |2026-11-16T01:35:44+01:002021-02-13|Construction basics|Comments Off on Recticel Eurothane Silver in a conventional warm roof: choosing the complete build-up

Fibre cement roofing for cattle housing: moisture, ventilation and durability

In a cattle shed, the roof works above a space where moisture is constantly generated. Fibre cement sheets can be a good covering for such a building, but their advantages only become apparent in a correct arrangement. Asbestos-free fibre cement must be considered together with ventilation, structure and the way the cattle shed is used day to day. Conditions in a cattle shed depend on the number of animals, bedding, washing and air exchange. A building with large openings in the walls has different needs from a tightly closed room. An assessment of a new roof should begin by checking where moist air currently leaves the interior. It is not worth treating marks on the old covering as proof that every leak comes from loose sheets.

By |2026-11-15T18:28:33+01:002021-02-01|Construction basics|Comments Off on Fibre cement roofing for cattle housing: moisture, ventilation and durability

What is bitumen-faced EPS, and when can it help with roof refurbishment?

A styropapa is an EPS board bonded to a layer of base roofing felt. It combines the function of thermal insulation with a prepared substrate for the subsequent covering layers. It can make work on the roof easier, but it does not replace an assessment of the old roof surface. Its use requires checking the substrate, moisture, fixing and the technology used to install the covering. The core is suitably selected polystyrene, and roofing felt is located on its surface. Lamination may be single-sided or double-sided, depending on the product. The boards come in specific formats and thicknesses. Some solutions have projecting felt overlaps that are used to make joints according to the manufacturer's instructions. In the documentation, for example, a format of 1000 × 1500 mm and a felt overlap 50 mm wide on two adjacent sides are found.

By |2026-11-16T06:07:55+01:002021-01-18|Construction basics|Comments Off on What is bitumen-faced EPS, and when can it help with roof refurbishment?

XPS at an industrial building plinth: protecting insulation near ground level

The lower band of the hall wall works under difficult conditions. Water splashed from the yard, snow and mud reach it. Vehicles move nearby, and the external substrate may be at a different temperature from the interior. XPS helps to limit the flow of heat through this zone. Extruded polystyrene, however, requires protection and a correct connection with the rest of the building envelope. A band of boards glued to the wall alone does not yet form a complete plinth. The plinth height must be considered relative to the final ground level. At the construction stage it is often considerably lower than the finished yard or pavement. If the designer and the contractor use different levels, part of the finish may later end up in the ground.

By |2026-11-16T06:07:16+01:002021-01-05|Construction basics|Comments Off on XPS at an industrial building plinth: protecting insulation near ground level